Vacuum & Gas Manifolds
Explore our selection, which includes double vacuum manifolds, double vacuum/inert gas manifolds, air sampling manifolds, vacuum manifold accessories, gas manifolds, and drying assemblies. These advanced systems ensure seamless operations, allowing you to easily manage vacuum and gas processes.
In this category, you'll find trusted brands such as SP Wildmad-LabGlass, Kemtech America, Ace Glass, Chemglass, Advantec MFS, and Sartorius, each renowned for their quality and innovation.
Experience the manifold benefits of our vacuum & gas manifolds, including enhanced laboratory efficiency and seamless vacuum and gas handling. Whether you need a Schlenk manifold, a vacuum manifold, or a gas manifold, our collection offers the highest precision and flexibility for your lab's operations.
Elevate your lab's vacuum and gas handling capabilities with our products, which provide a reliable performance for your scientific endeavors.
-
SYNTHWARE All Glass Vacuum/Inert Gas Manifolds
Kemtech AmericaWith 4mm double oblique, high vacuum hollow glass stopcocks precision ground with corresponding numbers on barrel and plug. Lower vacuum chambers on stopcock are evacuated with a separate hole in the plug in order to hold the plug in the stopcock barrels. Distance between stopcocks is 75mm center…
-
SYNTHWARE Nitrogen/Argon Manifolds
Kemtech AmericaWith 14/20 outer joint at the center to fit a rubber septum for keeping syringes under an inert environment cutting down on the number used.
-
Replacement thermocouple gauge tubes for AF-0301-01, AF-0301-02 or AF-0303-01.
-
Microsart 1, 3 & 6-branch manifold for Biosart 250 Funnels Equipment for the filtration of liquid samples in the microbiological quality control by vacuum; with Combisart base support for the use with Biosart 250 Funnels, with silicone tubing Pack size 1
-
Vacuum Traps, O-Rings, Airfree®, Schlenk
ChemglassTwo-piece vacuum trap with #15 o-ring joints on both the inlet and outlet ports. The seal between the trap stopper and body is made with a 57mm flat o-ring flange for total grease-free operation when used with either the AF-0060 or AF-0061 manifolds. Trap body is 57mm OD x 300mm in length to be…
-
Gas Manifold
Ace GlassFor portable gas analysis apparatus. Three or four straight 2 mm bore glass stopcocks and one three-way stopcock with back port, fabricated on capillary tubing. We can fabricate special gas manifolds of all kinds.
-
Patented screw-type valves within each SPE port for precise flow control Glass basin will not dissolve, fog, or discolor when exposed to solvents Legs on cover allow user to easily rest cover on work surface when removed from the manifold Screw-type solvent-resistant vacuum bleed gauge and…
-
SYNTHWARE Vacuum Manifolds, PTFE Stopcocks
Kemtech AmericaGeneral purpose manifold with 2mm or 4mm Teflon® stopcocks. Main tube is 22mm O.D. with serrated hose connection (10mm O.D.). Delivery ports have 10mm serrated hose connections. Distance between stopcocks is 75mm.
-
Stainless Steel Extraction Manifold
Advantec MFS1-place, 3-place, or 6-place Tapered branch accepts 40/35 female joint Choice of 2- or 3- way valves Vacuum manifolds allow filtration of multiple samples either at once or independently by controling the separate branch valves. The durable type 304 stainless steel can be used for…
-
SYNTHWARE Vacuum Single Manifold with #15 O-Ring Joints
Kemtech AmericaVacuum Single Manifold, High Vacuum Valves, #15 O-Ring Joints: Ports: 4, Valve Size: 0-8mm
-
Gas Manifold with Vacuum Chambers
DWK Life Sciences (Kimble)An all-glass manifold for connecting inert gas and vacuum sources. Double vacuum gas manifold with vacuum chambers. Fabricated from 1/2" medium wall tubing Stopcocks are 4 mm bore glass with lower vacuum chamber and are spaced 85 mm apart Top right connection is for inert gas and…
-
Drying Assembly, with Aluminum Holder
Ace GlassOriginally used for Lyophilizing and storing frozen slices of tissue for quantitative histochemistry (see O.H. Lowry, Journal of Histochem. & Cytochem., I, 420, 1953). More recently, used as a vacuum tube with aluminum holders by Nelson & Wakefield, Journal of Neuropathology & Exper. Neurology,…
-
Stainless Steel Vacuum Manifold
Thermo Scientific NalgeneNalgene 345 Solid and stable on the bench top Designed with three vacuum outlets, each with leakproof, two-way valve and vent port Each outlet securely holds a No. 8 stopper and the stem filter funnel without interference Autoclavable Easy manipulation of individual funnels…
-
SYNTHWARE Vacuum Manifolds, High Vacuum Valves
Kemtech AmericaWith a serrated hose connection (10mm O.D.) at left or right hand side. Main tube is 22mm O.D. and the distance between valves is 100mm center to center.
-
SYNTHWARE Double Manifolds, Hollow Glass Stopcocks
Kemtech America1164V90-V91 Double Manifold, Hollow Glass Stopcocks, Spherical Joints, 4 and 5 port manifold available, Joint Size: 35/20, Connections front-left right and rear-right, Overall Width: 365 and 450mm available. 1164V92 Double Manifold, Hollow Glass Stopcocks, Spherical Joints, Ports: 4, Joint…
-
Vacuum Manifold Accessories
SartoriusAccessories for Combisart and Microsart Combi.jet Vacuum Manifolds.
-
SYNTHWARE Vacuum Double Manifold with #15 O-Ring Joints
Kemtech AmericaVacuum Double Manifold, High Vacuum Valves, #15 O-Ring Joints: Ports: 4, Valve Size: 0-8mm
-
Single bank vacuum manifold with 0-8mm Chem-Vac™ Chem-Cap® valves mounted on a 45° angle to the user permitting easy operation inside of a fume hood. Ports are spaced 75mm center to center. All connection ports are #15 o-ring connections that incorporate a greasefree o-ring seal.…
-
Unique design, double bank manifold with the valves sealed in a vertical position. This design permits the user an unobstructed view of whether the valve is in the open or closed position while also exposing the PTFE valves to less outgassing (when the front bank of the manifold is used for inert…
-
SYNTHWARE High Vacuum Manifolds, Solid Glass Stopcocks
Kemtech AmericaWith 4mm double oblique, high vacuum solid glass stopcocks precision ground with corresponding numbers on barrel and plug. Solid glass stopcocks have constant pressure retention devices. Distance between stopcocks is 75mm center to center.
-
Double bank manifold available in 3, 4 or 5 port configuration. Forward facing 0-8mm Chem-Vac™ Chem-Cap® valves permit easy operation of manifold inside of a fume hood. Main ports are spaced 100mm center to center with an additional 2 ports on the upper bank that can be used for gauging…
-
Line has 5-ports with 4mm solid double oblique high vacuum stopcocks, CG-468-02, having a constant pressure retaining device, and 24/40 inner joints with hooks just above the grind. Ports are spaced 150mm center to center and have rod bracing to vacuum bank. Large ID of vacuum bank (40mm) provides…
-
Vacuum Gauges, Analog, 1000-1 Microns
ChemglassEconomical thermocouple gauge has fast response and high stability. Gauge is supplied either in a bench top case with handle or panel mount style. Gauge utilizes a 8-pin Hastings-Raydist DV-6M thermocouple gauge tube having a 10ft cord. Gauge tube is threaded with 1/8 " male NPT for use with…
-
Sterility Test Manifold
Advantec MFS1-place or 6-place Support cup accepts a No.8 or 8b stopper Features a flushing manifold Applications requiring a closed system, as in sterility testing, use the sterility test manifold. It features a rear-mounted flushing or rinse manifold pipe which allows liquid to be brought…
-
Manifold, Vacuum
Ace GlassAll-glass-and-PTFE vacuum manifold with three, four or five stopcock ports. Each port is a variable opening, 0-10mm, high vacuum threaded stopcock. Plugs are PTFE with Nylon or PTFE handles and FETFE O-Rings. Ultimate vacuum of 10-7 can be realized with O-Rings as supplied. For bakable systems,…
-
Double Vacuum Manifold
SP Wilmad-LabGlassThis borosilicate glass Air-Tite vacuum gas manifold (Schlenk line) is designed with double oblique pressure/vacuum stopcocks with 4mm bores and a 16.2/56 plug size. The stopcocks simplify evacuation or pressurization with an inert atmosphere. Manifold is 1" O.D.
-
SYNTHWARE Double Manifold, High Vacuum Valve
Kemtech AmericaThis manifold is designed to incorporate a 0-8mm high vacuum valve as the vacuum shut-off. The front tube is for inert gases (17mm O.D.), with a 10mm hose connection. The rear tube is for vacuum (22mm O.D.), with two 35/20 socket joints. Please order each component separately.
-
Main vacuum line with 4ea 24/40 inner ports (A) having a unique configuration of 0-4mm Chem-Vac Chem-Cap®; valves. The valves are sealed to either the vacuum or inert gas side of the manifold and then bent to a 90º angle, forming a strong but very compact assembly. This configuration…
-
Gas Manifolds, 4-Place, Glass Stopcocks
ChemglassFour port manifold with 2mm bore glass stopcocks on the ports. A "T"-bore stopcock is located 100mm from the end of the manifold and 40mm from the first port. The distance between the other 3 ports is 50mm with the last port being 75mm from the opposite end of the manifold. The entire…
-
Manifold, Tip-Off
Ace GlassUse to tip-off NMR tubes by inserting in lower Ace-Thred port and tightening via bushing. Vacuum line is connected to side hose connection. Tube is then tipped-off with flame. Aluminum shield helps retard heat transfer. Each port individually controlled by smooth acting, semi-needle, threaded PTFE…
-
Microfil Filtration System
MilliporeSigmaMicrofil® system uses presterilized, ready-to-use funnels and mem/lianes on a patented filtration support, cost-effective. Convenient, easy to use system for well-accepted mem/liane filtration method conforms to international standards: CEN, Standard Methods, WHO Disposable,…