Sample Preparation, Chromatography

Compare Tool

Select up to 3 products

HomeAll Products

Sample Preparation, Chromatography

1 - 32 of 131
Sort
View
Show
  • Oil-free vacuum pumps are piston powered, so they do not pollute the air and require minimal maintenance Quiet, low-vibration units keep disturbances to a minimum Built-in thermal protector automatically shuts off pump if it overheats and then restarts it once the unit is cool Inlet filter…

  • Luer lock inlet offers leak-tight syringe connection Variety of filter types, porosities, and diameters Color coded for easy identification Rugged polypropylene housing Autoclavable to 121°C for 15 minutes Quantity break pricing for greater savings Cellulose Acetate, Nylon,…

  • Sampling bags are a low-cost, whole-air sampling device for high-level VOCs and permanent gases. Several EPA, NIOSH, and OSHA methods exist for bag sampling for a variety of applications: stationary sources emissions; workplace atmospheres; ambient, indoor air quality; and breath analysis. Choose…

  • High-accuracy test gauges are recommended for verifying the vacuum/pressure in canisters before and after sampling. The 6-inch face on the analog gauge allows for easy reading. The digital gauge operates on two AAA batteries and offers an unambiguous readout. Both gauges have an accuracy of +/–…

  • Available for 2 mL, 15 mL, and 50 mL tubes Alphanumerical grid reference on top tier for easy identification of samples Easy to assemble; simply fold and snap together securely

  • Accurately and precisely dispense liquids for QuEChERS extractions with this versatile pump. A quick, simple adjustment lets you set the output volume anywhere from 2.5 mL to 30 mL per stroke, and the included adaptors will accommodate most reagent bottles. Adjustment knob offers 56 output…

  • Sampling bags are a low-cost whole air sampling device for high level VOCs and permanent gases. Several EPA, NIOSH, and OSHA methods exist for bag sampling for a variety of applications: stationary sources emissions; workplace atmospheres; ambient, indoor air quality; and breath analysis. Choose…

  • For ultimate inertness, SilcoCan air sampling canisters feature our unique Siltek treatment technology. Even highly active components, at low parts-per-billion concentrations, can be readily sampled and stored without loss. The RAVE valve is a high-quality, metal-to-metal seal, 2/3-turn valve with…

  • The model 1062 vacuum bag sampler provides fast sampling with zero cross-contamination. A vacuum created in the box draws air into the sampling bag without drawing it through the vacuum pump first, as is the case with standard air sampling pumps, thereby preventing contamination of the sample. This…

  • 2-inch vacuum/pressure gauges, 316 stainless steel with 1/8" NPT fitting and center back mount. Recommended for use with canisters.

  • These small canisters are designed for controlled sampling, such as personal air sampling, as an alternative to tube and pump samplers. The 1,000 cc canister is suitable for sampling volatile organic compounds in air according to methods TO-14A, TO-15, IP-1A, ASTM 5466, OSHA PV 2120, and NJ DEP Low…

  • Robust, low-flow pump optimized for sampling volatile organic compounds (VOCs) onto thermal desorption (TD) sorbent tubes Small, lightweight, easy to use, and intrinsically safe—ideal for personal monitoring and a wide range of other air and gas sampling applications Compatible with any…

  • Silica Gel 60 (230-400 Mesh) 25 Kg Silicar

    Avantor - Macron Fine Chemicals™

    For Column Chromatography Grade: SilicAR CAS Number: 63231-67-4 HTS Number: 2811221000 Specific Gravity: 1L = 2.10 Kg Management of Change: N

  • General Description For continuous "hands off" direct transfer of multiple liquid samples A Visiprep large volume sampler enables you to transfer low viscosity samples directly from any sample container to conventional solid phase extraction tubes on a Visiprep SPE vacuum…

  • Swagelok sample cylinders are made of 304L and 316L stainless steel to resist corrosion and DOT rated to 1,800 and 5,000 psig (TPED cylinders rated to 1,450 and 4,350 psig), which allows sampling at gas wellheads as well as on-site refineries. Each cylinder is hydrostatically tested to at least 5/3…

  • QuEChERS methods are fast, easy, and cost-effective, and Restek Q-sep products make QuEChERS procedures even simpler. All extraction salts, sorbents, and sample tubes are included—no specialized equipment or glassware is required. Prepare samples more efficiently with a complete line of…

  • Optimized for Methods TO-14A, TO-15, IP-1A, ASTM D5466, OSHA PV 2120, and NJ DEP Low Level TO-15 Proprietary electropolished surface maintains compound stability. High-quality, metal-to-metal seal, 2/3-turn valve with stainless steel diaphragms prevent sample adsorption for more-accurate…

  • Unwashed PUF plugs for both low-volume and high-volume sampling Flame retardant free—making them easier to clean for trace analysis Compliant with EPA and ASTM methods—0.022 g/cm 3 density Glass holders sold separately

  • Single-stage, stainless steel Two pressure gauges and CGA-180 fitting Stainless steel diaphragm and Kel-F seat Accurate pressure control even at low flow rates Individually tested for leaks and impurities

  • Free-flowing salts transfer easily and completely. Easy-open packets eliminate the need for a second empty tube for salt transfer. Convenient slim packets fit perfectly into tubes to prevent spills. Ready-to-use tubes, no glassware required. Pre-weighed, ultra-pure extraction salts. …

  • Equivalent to XAD-2 Resin—Exclusively from Restek! Ultra-Clean resin typically eliminates the hassle of cleaning and testing resin for air sampling. For adsorbing semivolatiles in air. Cleaned and GC tested. Available in 100 gram quantities.

  • Includes fitting and orifice.

  • Anhydrous sodium sulfate is the most common drying agent used to remove moisture from sample extracts. We package our 10-60 mesh material in recloseable buckets. Ideal for removing water from sample extracts Activate by heating to 400°C for four hours before use Packaged in…

  • Cleaned, assembled, and ready to use Clear or amber glass Caps and PTFE-lined septa included

  • Sampling bags are a low-cost whole air sampling device for high level VOCs and permanent gases. Several EPA, NIOSH, and OSHA methods exist for bag sampling for a variety of applications: stationary sources emissions; workplace atmospheres; ambient, indoor air quality; and breath analysis. Choose…

  • Suitable for a wide range of analyte chemistries and sample matrices Reliable performance meets or exceeds other brands Robust aluminum hub is more durable than plastic Optimized for PAL system autosamplers and compatible with most GC inlets SPME automated sample preparation reduces…

  • Reduces pressure between sample cylinder and GC injector Maintains fine metering control Contains Kel-F seat

  • 0–300 psig inlet pressure range 0–15 psig outlet pressure range Supplied with 0–15 psig outlet pressure gauge, brass CGA 170 nut and nipple, and 1/8-inch compression outlet

  • Use the Resprep sample delivery system to transfer large volumes of low viscosity samples directly from a bottle to a solid phase extraction cartridge, or to a disk on a vacuum manifold system for extraction or cleanup. Each unit consists of six transfer lines with a stainless steel weight on one…

  • PTFE wetted parts are highly resistant to corrosive gases Diaphragm-based pump is low maintenance and virtually pollution free Quiet, low-vibration units keep disturbances to a minimum Built-in thermal protector automatically shuts off pump if it overheats and then restarts it once the…

  • Use a luer lock valve adaptor to connect a luer lock fitting to a Rheodyne or Valco valve.

  • Compatible with most vacuum manifold systems that accept 1/8-inch male luer fittings Sample can be automatically introduced via 1/8-inch PTFE tubing or from the optional Diskcover-47 reservoir

Compare Tool

Select up to 3 products

Please Log In

Don't have a web profile? Create one now.