NARROW RESULTS BY
Category
Manufacturer
Viscosity Standard No.
Standards
-
General Purpose Viscosity Standards
Cannon InstrumentBased on NIST value of 1.0016 centipoise for water at 20C; conforms to ASTM Standards D 445, D 88 and D 2161; traceable to NIST Approximate viscosities at varying temperatures in centistokes and centipoises are given in Table 1; each standard is furnished with actual viscosity and density…
Related Products: Viscosity Standard
-
Fungilab's silicone rotational viscosity standards are essential for the calibration of rotational viscometers. Silicone standards are ISO 17025 / ISO Guide 34 certified and are ready to use in convenient 600mL packs, eliminating the need to transfer sample fluids to a test beaker.…
Related Products: Brookfield Viscosity Standard
-
High Viscosity Standards
Cannon InstrumentFor determining viscosities in asphalt and polymers (see ASTM D 2170 and D 2171) Traceable NIST For Kinematic Viscosity Values (cSt), please contact Thomas Scientific
Related Products: Viscosity Standard
-
Cold Cranking Simulator Viscosity Standards
Cannon InstrumentConform to SAE specification J300 and ASTM D 5293 Viscosities based on NIST value of 1.0016 centipoise for water at 20°C Traceable to NIST Supplied in one pint bottles
Related Products: Cannon Viscosity Standards
-
Paint Viscosity Standards
Cannon InstrumentFor Thomas®-Stormer® Viscometers Based on NIST value of 1.0016 centipoise for water at 20°C. Traceable to NIST. Approximate viscosity in centipoise and Krebs unit values at 25°C are given in table below. Actual value are furnished with each standard. Supplied in a one pint bottle.
Related Products: Paint Viscosity
-
General Purpose Low Temperature Viscosity Standards
Cannon InstrumentCANNON Low Temperature Viscosity Standards verify viscometer performance at sub-zero temperatures. These standards are applicable to SAE Specification J300 as well as a variety of ASTM Methods including: ASTM D2983, Low-Temperature Viscosity of Lubricants Measured by Brookfi eld…
Related Products: Viscosity Standard
-
Silicone Viscosity Standards
Cannon InstrumentFor calibration of rotational viscometers Viscosity certified at 20, 23, 24, 25, 26 and 27°C Calibrated to a precision of ±0.2% NIST traceable Standards are based on the National Institute of Standards and Technology (NIST) value of 1.0016 mPa-s (centipoise) for…
Related Products: Cannon Viscosity Standards
-
Viscosity Standard, -20 and -25°C for CMRV, 500 ml
Cannon InstrumentFor preceding the borderline pumping temperature of engine oil in accordance of ASTM Standards D 3829 and D 4684 Viscosity of 30,000 centipoise at -20°C based on NIST value of 1.0016 centipoise for water at 20°C; traceable to NIST
Related Products: Cannon Viscosity Standards
-
Methyl Salicylate
MilliporeSigmaAnalytical Standard for gas chromotagaphy. Synonym: 2-Hydroxybenzoic acid methyl ester, Methyl 2-hydroxybenzoate, Oil of wintergreen, Wintergreen oil Linear Formula: 2-(HO)C6H4CO2CH3 Molecular Weight: 152.15
Related Products: Methyl Salicylate
-
General Purpose Viscosity Standards
FungilabViscosity standards are ideal for the calibration of dynamic and kinematic viscosity instrumentation. Standards are supplied at 500mL and must be used with a supplementary beaker. All viscosity standards are delivered with a certificate of analysis and are ISO 17025 / ISO Guide 34 certified.…
Related Products: Viscosity Standard
-
Bond Elut NEXUS
Agilent TechnologiesBond Elut NEXUS is an ultra-clean, large particle size polymeric SPE ideal for highly viscous samples, available in non-polar or weak cation exchange.
-
Bond Elut Sodium Sulfate Drying Cartridges
Agilent TechnologiesBond Elut Sodium Sulfate Drying Cartridges simplify drying processes with pre-packed devices.
Related Products: Sodium Sulfate Drying Cartridge
-
High-Temperature Viscosity Standards
Cannon InstrumentFor use with Cannon High Temperature/ High Shear Viscometers for measurements at 150°C and 10 -6 s -1 shear rate Based on NIST value of 1.0016 centipoise for water at 20°C; traceable to the NIST In accordance with ASTM Standard D 4624 9727U92 and U94 are non-Newtonian…
Related Products: Viscosity
-
-
DGA Resin
EichromEichrom’s DGA Resins are extraction chromatographic materials in which the extractant system is either N,N,N’,N’-tetra-n-octyldiglycolamide (DGA Resin, Normal) or N,N,N’,N’-tetrakis-2-éthylhexyldiglycolamide (DGA Resin, Branched). The bed density of both DGA Resins is approximately 0.38 g/mL, with…
Related Products: Dga
-
-
20mL Empty Columns
EichromThese columns, nominally 20mL, have an inner diameter of 1.5 cm and a "packable" volume of 17mL. Use them when a large bed volume of one of Eichrom's extraction chromatography or ion exchange resins is required. Columns are supplied with bottom frit pre-inserted, in packages of 20,…
Related Products: Empty Column
-
TRU Resin
EichromEichrom's TRU Resin is an extraction chromatographic material in which the extractant system is octylphenyl-N,N-di-isobutyl carbamoylphosphine oxide (abbreviated CMPO) dissolved in tri-n-butyl phosphate (TBP). The bed density of TRU Resin is approximately 0.37 g/mL, with a working capacity of 2 mg…
Related Products: Tru Resin
-
Sr Resin
EichromThe extractant system in Eichrom's Sr Resin is 1.0M 4,4'(5')-di-t-butylcyclohexano 18-crown-6 (crown ether) in 1-octanol.A 40% (w/w) loading of this organic solution is loaded onto an inert chromatographic support. The bed density of Sr Resin is approximately 0.35 g/mL.
Related Products: Eichrom
-
UV-Vis Standards And Reagents
Agilent TechnologiesIn recent years, quality requirements as outlined by ISO 9000, GLP, GMP and NAMAS have assumed increasing importance. As a consequence, the recommendations of pharmacopoeias have become more influential in the pharmaceutical industry. Formal performance verification of UV-Visible spectrophotometers…
Related Products: Uv Vis Standards
-
TEVA™ Resin
EichromOne of the more versatile of Eichrom's analytical products is TEVA Resin. It has been applied on a routine basis to the analysis of technetium, the measurement of the tetravalent actinides, and the separation of americium from lanthanides. It is used alone or can be readily combined with other…
Related Products: Teva Resin
-
LC And GC/MS Standards And Reagents
Agilent TechnologiesGPC-SEC Calibration Standards (2714X77 to X79) Three different polystyrene standard kits are available for organic GPC column calibration. Each kit contains individual monodisperse polymers that cover low, medium and high molecular weight ranges. Each standard lot is characterized using low-angle…
Related Products: Polyethylene Glycol 600
-
Ink and Paint Viscosity Standards
Cannon InstrumentFor ink and paint viscometers For use with Zahn, Shell and Ford viscometer cups. Based on NIST value of 1.0016 centipoise for water at 20°C. Traceable to NIST. Approximate kinematic viscosity and drain times for the various cups at 25°C are given in table. Actual values are furnished…
Related Products: Zahn Cup Viscometers
-
Certified Viscosity “Check Oils” for SAE Target Viscosities
Cannon InstrumentCANNON Instrument Company has released a line of viscosity check oils specifically designed for verification of SAE target viscosities per ASTM D 445, D 5293, and D 4684. The CVCO (Certified Viscosity Check Oil) series includes formulated commercial engine oils with certified values for kinematic…
Related Products: Kinematic Viscometer
-
Gas Analyzer Standards And Accessories
Agilent TechnologiesGas Analyzer Standard Kits (2714T95 to T97) Calibration kits contain one box of 2 calibration mix cylinders, 2 regulators, 2 pieces of stainless steel 1/16 in. gas sampling tubing, and 1 carry case, all packaged separately. Gas Analyzer Standard Cylinders (2714T90 to T94) Cylinder…
Related Products: Gas Cylinder Regulator
-
SPEC Disk SPE
Agilent TechnologiesSPEC Disk SPE delivers superior flow characteristics and trouble free automation.
-
Bond Elut C8
Agilent TechnologiesBond Elut C8 is very similar in property to C18, but is not as retentive for non-polar compounds due to its shorter hydrocarbon chain and therefore reduced carbon loading. C8 is an excellent replacement for C18 when analytes are too strongly-retained for effective elution. The potential for polar…
-
Cartridge Vacuum Box
EichromThis 24 hole vacuum box has a high density polyethylene (HDPE) top for acid compatibility and a clear plastic bottom for visibility of collection tubes. Overall dimensions are 57 cm (long) x 14.5 cm (deep) x 18 cm (high.) The box comes complete with a screw in vacuum gauge, a rack insert which…
-
-
Agilent GC Column Test Standards
Agilent TechnologiesColumn Test Standards validate the performance of your Agilent columns by checking such components as polarity and inertness. These standards help ensure the quality of your chromatograms.
-
Bond Elut C18
Agilent TechnologiesBond Elut C18 is the most hydrophobic silica sorbent available in this range. It is the most popular SPE sorbent because of its extreme retentive nature for non-polar compounds.
Related Products: C18 Sorbent