Sterilization & Biological Indicators
-
1251D01 detects the presence of Bacillus stearothermophilus spores 1251D07 detects the presence of Bacillus subtilis spores 1251D01 indicators are designed for monitoring 270°F (132°C) gravity steam sterilization processes. Detection media will turn yellow in the event of a…
-
3M™ Comply™ Bowie-Dick Test Packs are used to monitor the performance of vacuum-assisted 132ºC - 134ºC (270ºF - 273ºF) steam sterilizers; test packs will reproducibly detect residual air in the sterilizer chamber due to air leaks, air removal failures and inadequate…
-
Duo-Spore® Biological Indicator System
Propper ManufacturingFor monitoring the efficacy of steam, ethylene oxide gas, chemical vapor and dry heat sterilization processes used in healthcare facilities, body modification parlors and industry. Biological monitoring is recommended weekly, but preferably daily, and with every load containing implants.…
-
Vapor Line® Steam Sterilization Integrators
Propper ManufacturingThe Vapor Line® integrator is a chemical indicator for monitoring the essential conditions of steam sterilization processes - saturated steam, temperature, and time in gravity displacement and pre-vacuum sterilizers operating in the 250°F - 272°F temperature range. The integrator…
-
Steri-Dot® Indicators
Propper ManufacturingSelf-adhesive Steri-Dot® Indicators offer a fast, positive visual check on items that were sterilized by Ethylene Oxide gas. They also display a Red for Stop, Green for Go color scheme. A Red Steri-Dot® indicates that the package or load has not yet passed through sterilization - a Green…
-
Sure-Check® Sterilization Pouches
CrosstexSure-Check Pouches with built-in internal/external multi-parameter steam sterilization indicators confirm all sterilization criteria—time, temperature and presence of steam. Until now, due to limitations in technology, sterilization pouches have had only single parameter chemical…
-
Steri-Wrap® III
Propper ManufacturingA strong wrap especially suitable for heavy instrument trays Features: Efficient microbial barrier and provides for pack security Virtually lint free and has a tightly anchored fiber structure Does not delaminate and can be used on either side Excellent liquid repellency and…
-
VERIFY™ Dual Species Self-Contained Biological Indicators (SCBIs) are for use in monitoring steam sterilization and ethylene oxide (EO) sterilization processes. Each SCBI is completely self contained within a vial and contains a disc inoculated with dual species bacterial spores (Geobacillus…
-
Ethylene Oxide (EO) Chemical Process Indicators (CPIs) are manufactured to meet performance specifications described in ISO 11140-1 “Sterilization of health care products - Chemical indicators - Part 1: General requirements,” for Class 1 Process Indicators. The purple-to-green color…
-
Record Keeping Envelopes
Propper ManufacturingSeparate color-coded envelopes for steam and EO gas sterilization: Each envelope is specifically designed for its sterilization process, and contains checklists for operators All essential data is in one place: Each envelope holds charts, indicators, Duo-Record cards and biological monitoring…
-
PASS/FAIL® Steam Challenge Pack
Propper ManufacturingA single-use test pack designed to provide a challenge to 250°F gravity displacement and 273°F prevacuum sterilizers in modern hospital practice. Equivalent in performance to a biological indicator in the AAMI approved linen pack. Propper PASS/FAIL® Steam Challenge Pack PASS…
-
Strate-Line® Steam Sterilization Strips
Propper ManufacturingStrate-Line Sterilization Indicator Strips are an economical alternative to OK strips and are designed for monitoring steam sterilization cycles at 250°F (121°C) and 273°F (134°C). It uses the same reactive ink as the OK strip. The correct endpoint is indicated when the…
-
Kimtech™ Kimguard™ KC600 Sterilization Wrap (68654) 54ö x 54ö 48/cs
Kimberly-Clark ProfessionalKimtech™ Kimguard™ Sterilization Wrap is a must-have tool for sterile processing environments, such as in pharmaceuticals and medical devices. The line comes in six grades of wrap fabric, from KC 100 to KC 600, so you can get precisely the right protection for your needs. The…
-
Self-Seal Sterility Maintenance Covers
Propper ManufacturingPlastic dust covers protect the sterile pack during storage, handling, and transportation from dust, moisture, or airborne contaminants, and extend sterile shelf life when definite shelf life terms are used. Self-Seal Dust Covers satisfy current regulations for sterility maintenance covers.
-
Steam Dot® Blu™ Indicators
Propper ManufacturingSteam Dot Blu™ utilizes the latest in environmentally friendly inks: the Blu™ ink technology. All products made with Blu™ inks are free of all heavy metals, including lead. Environmentally Friendly Technology: Manufactured without lead & heavy metals …
-
Steam Sterilization Monitor Strips are used for evaluating sterilization process. These indicators which are specified by the U.S. military specification MIL-S- 36586 are GMP requirements of U.S. FDA. Appearance: Filter paper strip impregnated with spores of standard culture of…
-
Dry Heat Sterility Tape
DynalonAdhesive tape for use with dry heat sterilization. Use these tapes to enhance confidence that sterilization has occurred. Color changes from white to brown. Conforms with ISO 11140/2005
-
Gas-Chex® Sterilization Indicators
Propper ManufacturingGas-Chex® Sterilization Indicator Strips have the easiest-to-remember color scheme: Red for Stop (pack was not yet processed or the process was inadequate), and Green for Go. Gas-Chex® Strips are suitable for monitoring gas concentration and exposure, and are especially suitable for…
-
Nonslip Sterility Maintenance Covers
Propper ManufacturingPlastic dust covers protect the sterile pack during storage, handling, and transportation from dust, moisture, or airborne contaminants, and extend sterile shelf life when definite shelf life terms are used. Nonslip Dust covers satisfy current regulations for sterility maintenance covers.
-
Paper Heat-Seal Sterilization Pouches
Cardinal HealthCardinal Health™ Paper Sterilization Pouch combines a blue film and a medical grade paper to provide breathability, sterile barrier, and indication of processing. Each pouch includes an external process indicator for Steam and Ethylene Oxide (EO) Gas sterilization. To assist opening, a…
-
-
B/T Sure™ Biological Indicators
BarnsteadVerifies the sterility of your instruments, glassware and other products in just two days Simple, three step process Run indicator through standard sterilization cycle; compress plastic vial to break glass ampule inside and then incubate for a minimum of 48 hours. When complete,…
-
Crosstex manufactures Bacillus subtilis (Cell Line 6633) Spore Suspensions utilized in low temperature (<121°C) steam sterilization processes. The Spore Suspensions are pure suspensions of spores with known steam resistance characteristics and a variety of population levels standardized per…
-
OK® Sterilization Indicator Strips
Propper ManufacturingFor steam sterilization cycles of 250°F (121°C) and 273°F (134°C) OK® Strips are indicators that monitor all critical sterilization arameters: steam, time, and temperature. In sterilization cycles OK® Strips guard against incomplete steam penetration, presence of…
-
O.K.® Sterilizer Bags
Propper ManufacturingThese all-paper, high quality, gusseted sterilization packaging bags are available in three sizes and are manufactured to meet stringent requirements. The exterior of each bag carries a pre-printed process indicator to allow easy identification of packs that have been subjected to the steam…
-
Mini Self-Contained Biological Indicators (SCBIs) for Monitoring Steam Sterilization Processes, Geobacillus stearothermophilus Cell Line 7953, SCBIs each 8.4 mm x 45.5 mm, 10 5 population level, 25 per box, ISO 11138-1, 11138-3 and USP compliant where applicable.
-
Twindicator® Sterilization Indicators
Propper ManufacturingTwindicator® is an indicator designed for monitoring all critical parameters of steam sterilization cycles at 250°F (121°C) and 273°F (134°C). Twindicator® adds extra flexibility in sterilization monitoring: each 8” strip is perforated to allow for two 4” strips.…
-
Biological Chemical Indicator Strips
Thermo ScientificChemical indicator strips, for use with steam sterilizers, require a temperature of 132 to 135°C (270 to 275°F). Daily verification ensures that items being processed have been run through a cycle, preventing the accidental use of items that have not been adequately processed.
-
Chex-All® Sterilization Pouches
Propper ManufacturingHeat-Sealable Chex-All® Pouches are premium quality sterile packaging products designed to reduce the cost of sterilization processing. The pouches have independent indicators imprinted on both inside and outside of every pouch. While external indicators serve as process indicators, the…
-
Kimtech™ Kimguard™ KC100 Sterilization Wrap
Kimberly-Clark ProfessionalKimtech™ Pure Kimguard Sterilization Wrap is a must-have tool for sterile processing environments, such as in pharmaceuticals and medical devices. The line comes in six grades of wrap fabric, from KC 100 to KC 600, so you can get precisely the right protection for your needs. The higher the…
-
SporAmpule® Liquid Biological Indicators
Hardy DiagnosticsMonitoring your autoclave couldn’t be easier with the convenient SporAmpule. Easy to use! Process one or more SporAmpules, along with your normal load, then incubate at 55-60°C for 48 hours and observe for a color change. No activation, crushing, or additional culture media is…
-
Sterikon Plus Biological Sterilization Indicator
MilliporeSigmaFor monitoring the effectiveness of steam sterilization at 121°C for 15 minutes Easy-to-read; media’s color changes with growth Rapid results; read after 24 hours Sterikon ® Plus indicators contain nutrient broth, sugar, a pH indicator and spores of apathogenic bacillus…