Gas Chromatography Tools
-
Methane Dual Stage Tank Regulator
PerkinElmerMethane and hydrogen regulator, two stage HP Brass regulator, SS diaphragm, Delivery Pressure 0-50 PSIG, 1/8 Ultra-Torr Fitting.
-
-
Gas Chromatography Male Fitting
PerkinElmerThe PerkinElmer 1/16 Inch gas chromatography male fitting comes with a 10-32 thread that offers great connection and the brass construction offers added strength.
-
1/16in Rheodyne Ferrule
PerkinElmerPerkinElmer offers a variety of stainless steel, titanium and polymer based nuts, ferrules, unions and tubing for plumbing the components of your LC system.
-
A complete stainless steel body nebulizer with stainless steel capillary and Viton o-rings. Recommended for use with aqueous solutions. This nebulizer is compatible with the PinAAcle 500 and 900F/H/T AA instruments. Note: This nebulizer ships as standard equipment on instruments configured with a…
-
The PC 3 is a small, robust Peltier cooled cyclonic spray chamber. The PC 3 offers the advantages of low memory effects, constant temperature, fast rinse-out, and high sample transport efficiency. The cooled outer walls of the PC 3 spray chamber enhance long-term signal stability, reduce…
-
ICP-OES Compressor/Tank/Dryer, 115V/60Hz
PerkinElmerA great choice when quiet, dependable and clean air is a must. Each compressor comes assembled on an internally and externally coated air tank and includes a self-purging regenerative dryer withaftercooler. The version with the sound enclosure has a sound level of less than 60 dB. Models in 115 V…
-
Includes the TGA 8000 Sub-ambient Cooling Tube (N5370333), Hose clamps (09903004) and tubing (02506518) for connecting the Cooling Tube to the Chiller, and Instructions. When combined with the Chiller Accessory (N5370220 for 120V operation or N5370221 for 220 Volt operation) provides the ability to…
-
Retrieving Wire for the PerkinElmer 2400 Tube Removal
-
-
-
Extension Probe
PerkinElmerThe PerkinElmer extension probe is made from quality quartz material and is used in the process of dynamic and thermo mechanical analysis.
-
A complete High Sensitivity plastic body nebulizer with Pt/Ir capillary and Kalrez o-rings. The nebulizer is compatible with the PerkinElmer AAnalyst 100/300/700/800 as well as Model 5100PC/5000/3300/3110/3100 AA instruments.
-
The sealed liquid cells have a corrosion-resistant construction making them ideal for highly volatile samples. The sealed liquid cells are ideal for quantitative analysis where you require an accurate reproducible cell thickness. These cells use a lead spacer which is amalgamated to the window…
-
-
PerkinElmer cells ensure top optical performance, with high celltransmission and accurate pathlength. The cell windows are fused tothe bodies by a special process which avoids deformation of thewindows. This assures that the full width of the cell is usable andthe finished cell dimensions are…
-
-
Standard rectangular Macro cells are the most common type of spectroscopy cell and are used for routine UV/VIS analysis. Each cell has a standard inside width of 9.5 mm and a base thickness of 1.5 mm. All Macro cells contain two clear windows.
-
Union Tees
SGESuitable for glass lined tubing (GLT™), metal and plastic tubing Non-swaging fittings that will not deform tubing Easy to remove tubing no back ferrule required
-
15% graphite / 85% polyimide ferrule recommended for use with GC/MS systems. Temperature limit is 350 °C.
-
RheoFlex PEEK Ferrules
PerkinElmerPerkinElmer offers a variety of stainless steel, titanium andpolymer based nuts, ferrules, unions and tubing for plumbing thecomponents of your LC system.
-
50mm Rectangular Cell Holder
PerkinElmerA comprehensive range of FT-NIR cells are available for use with PerkinElmer FT-NIR’s and can be found in the cells listing included in the UV section of this catalog.
-
-
Nano Stick-D, Z 15 Black 2 µL 0.5 mm
PerkinElmerEach Nano Stick standard package kit (with case) comes with 1 Nano Stick, 1 loading plate, 1 bubble checker, and a user guide. The preferred color of your choice can be selected (Black, Blue, Red, Gold, or Silver). The Z-Dimension, the height of the center of the light beam, is 15 mm. The beam…
-
Combustion Tube for CHN Analysis, Quartz
PerkinElmerFused quartz has been chosen because of its very high purity and low thermal expansion rate. Because we care about your safety, all combustion tubes are pressure-tested to eliminate any tubes which might contain weak spots. In addition, stringent specifications are used to insure that the…
-
-
Acetylene Regulator
PerkinElmerFor AA labs, this regulator includes an adapter so that the pressureregulator can be connected to cylinders requiring either CGA 300 orCGA 510 fittings and a connector for attaching the fuel hose assemblysupplied with the instrument. Includes hose assembly.
-
PerkinElmers quartz probes are manufactured to extremely high tolerances to ensure you obtain the most accurate data from your instrument.
-
The PC 3 is a small, robust Peltier cooled cyclonic spray chamber. The PC 3 offers the advantages of low memory effects, constant temperature, fast rinse-out, and high sample transport efficiency. The cooled outer walls of the PC 3 spray chamber enhance long-term signal stability, reduce…
-
Automatic water thermostattable automatic linear cell changer for eight samples and eight references. Includes: Automatic Linear Transport (B2000186), Reference Kit (B2000310), and two 8-CellHolders (B2205411). No accessory PCB required.
-
A complete stainless steel body nebulizer with stainless steel capillary and Kalrez o-rings. Recommended for use with aqueous or organic solutions. This nebulizer is compatible with the PinAAcle 500 and 900F/H/T AA instruments.
-
ICP-OES Oil-less Air Compressor, 220V/60HZ
PerkinElmerHorse Power: 1.5 Hp Output CFM/Output L.: 6.0 CFM/170 L. Min Max Pressure PSI/Max Pressure Bar 120 PSI/8 bar Noise Level: 72 dB/A, with Enclosure 55 dB/A Tank Size Gal./Tank Size L: 13 Gallons/50 Liters Dimensions: 25 x 18 x 29 / with Enclosure 29 x 23 x 32 Weight: 97 Lbs. / with…