YMC

Compare Tool

Select up to 3 products

1 - 32 of 157
Sort
View
Show
  • C8 is the most commonly used column type following C18. YMC Octyl columns are prepared from exhaustive bonding of a monomeric octylsilane to totally spherical and porous silica gels. The functionalized silica is then treated with a endcapping process. Application: For Anti-Human Immunodeficiency…

  • ODS-AQ is a unique reversed-phase material with both a hydrophobic high carbon loading and a relatively hydrophilic surface. Because of the hydrophilic surface, ODS-AQ can be "wetted" with polar eluents. ODS-AQ provides chromatographers reproducible retention and excellent peak shape in highly…

  • ODS-A is a high coverage, fully endcapped C18 phase which exhibits exceptional batch-to-batch reproducibility. ODS-A columns are noted for their high efficiency, selectivity and long lifetimes. Application: For Analgesics, Carotene Highly versatile ODS phase Selectivity for polar to moderately…

  • In a reversed-phase mode, Cyano columns are the most polar and least retentive of all reversed-phase packings. Extremely hydrophobic compounds, which do not elute on standard C18 and C8 packings with typical reversed-phase eluents, can be chromatographed using Cyano columns. In addition, the unique…

  • YMC America column coupler is a single- and double-end connector. Stainless tube 50 mm×1, male nut×2, ferrule×2)

  • ODS-AQ is a unique reversed-phase material with both a hydrophobic high carbon loading and a relatively hydrophilic surface. Because of the hydrophilic surface, ODS-AQ can be "wetted" with polar eluents. ODS-AQ provides chromatographers reproducible retention and excellent peak shape in highly…

  • Phenyl columns provide unique selectivity when compared to aliphatic straight chain reversed phases such as ODS, C8 and C4. The p electrons of the phenyl group can interact with the aromatic ring of an analyte to increase retention relative to non-aromatic species. Phenyl also has application as an…

  • SUMICHIRAL OA columns are high-performance chiral columns for enantiomer separation by HPLC. On SUMICHIRAL OA columns direct separation of various enantiomers can be realized effectively. Enantiomeric separation is achieved from the various diastereomeric interactions such as hydrogen bonding,…

  • YMC-Triart C8 is a versatile column with excellent chemical durability that is equivalent to YMC-Triart C18. YMC-Triart C8 is suitable for fast analysis of samples containing hydrophobic compounds that are strongly retained on C18 columns or samples containing compounds with large differences in…

  • C8 is the most commonly used column type following C18. YMC Octyl columns are prepared from exhaustive bonding of a monomeric octylsilane to totally spherical and porous silica gels. The functionalized silica is then treated with a endcapping process. Application: For Anti-Human Immunodeficiency…

  • The high purity silica found in YMC-Pack Silica columns provides virtually complete sample recovery. The absence of silica impurities reduces non-specific sample adsorption which lowers sample recovery and may cause unusual peak shapes. The totally porous nature of the silica found in YMC-Pack…

  • YMC-Pack ODS-A has a highly endcapped surface structure and appropriate hydrophobicity for separation of a wide range of compounds. It is produced under strict quality control with respect to 50 or more parameters in order to ensure stable quality. This product is highly regarded as the standard…

  • YMCbasic is a unique reversed-phase column designed for analysis of pharmaceuticals and other basic compounds. YMCbasic utilizes a novel silica synthesis and state-of-art silane bonding to create a column which gives true reversed-phase character, high resolution and excellent peak shape for the…

  • The high purity silica found in YMC-Pack Silica columns provides virtually complete sample recovery. The absence of silica impurities reduces non-specific sample adsorption which lowers sample recovery and may cause unusual peak shapes. The totally porous nature of the silica found in YMC-Pack…

  • All phases in the Pro-family are ideal for the analysis of all types of organic molecules but specifically basic and metal chelating compounds. The ultrapure silica and very low residual silanol activity means that these columns frequently do not require the use of ion-pairing reagents or…

  • YMC-Actus series are semi-preparative HPLC columns that have excellent column durability and efficiency by applying axial compression technology. YMC-Actus series columns show high durability under high flow rate or steep gradient conditions and desirable for milligram scale preparative HPLC of…

  • YMC-Triart C8 is a versatile column with excellent chemical durability that is equivalent to YMC-Triart C18. YMC-Triart C8 is suitable for fast analysis of samples containing hydrophobic compounds that are strongly retained on C18 columns or samples containing compounds with large differences in…

  • Meteoric Core products feature ultra fast separation and outstanding resolution, excellent peak shape on basic and coordination compounds, a wide usable pH range, and a low column bleed.

  • YMC-Pack Diol is a size exclusion chromatography column utilizing a silica gel base. Diol-120, 200, and 300 are suitable for separation or molecular weight determination of proteins with molecular weights of 10,000 to 1,000,000. Diol-60 is the most suitable for separation of peptides of…

  • C8 is the most commonly used column type following C18. YMC Octyl columns are prepared from exhaustive bonding of a monomeric octylsilane to totally spherical and porous silica gels. The functionalized silica is then treated with a endcapping process. This produces a moderate 10% carbon loading on…

  • YMC-Pack C4 (Butyl) columns are less hydrophobic than C8 or C18 packings, and generally utilize more aqueous eluents than either of these reversed phase column types. When compared to C8 and C18 columns using the same eluent, C4 columns show significantly shorter retention for non-polar compounds.…

  • In a reversed-phase mode, Cyano columns are the most polar and least retentive of all reversed-phase packings. Extremely hydrophobic compounds, which do not elute on standard C18 and C8 packings with typical reversed-phase eluents, can be chromatographed using Cyano columns. In addition, the unique…

  • ODS-AM is a high carbon load C18 packing that is similar in selectivity to ODS-A. The major difference between these bonded phases is that ODS-AM has extremely tight specification criteria which provides excellent peak shape and more reproducible separation. Application: For Alkaloids Long-term…

  • C8 is the most commonly used column type following C18. YMC Octyl columns are prepared from exhaustive bonding of a monomeric octylsilane to totally spherical and porous silica gels. The functionalized silica is then treated with a endcapping process. Application: For Anti-Human Immunodeficiency…

  • BioPro IEX Columns are for the separation of proteins, peptides, and nucleic acids. BioPro IEX Columns are available in QA and SP chemistries and are based on porous (QA and SP columns) and non-porous (QF and SF columns) hydrophilic polymer beads with low nonspecific adsorption. The porous…

  • SUMICHIRAL OA columns are high-performance chiral columns for enantiomer separation by HPLC. On SUMICHIRAL OA columns direct separation of various enantiomers can be realized effectively. Enantiomeric separation is achieved from the various diastereomeric interactions such as hydrogen bonding,…

  • YMC-Triart C18 is a hybrid silica-based ODS column emphasizing durability, low operating pressure, and excellent performance. YMC-Triart C18 has been developed and is manufactured using state-of-the-art technologies that define materials, granulation, and surface modification. Application: For…

  • ODS-AM is a high carbon load C18 packing that is similar in selectivity to ODS-A. The major difference between these bonded phases is that ODS-AM has extremely tight specification criteria which provides excellent peak shape and more reproducible separation. Application: For Alkaloids Long-term…

  • YMC-Pack Diol is a size exclusion chromatography column utilizing a silica gel base. Diol-120, 200, and 300 are suitable for separation or molecular weight determination of proteins with molecular weights of 10,000 to 1,000,000. Diol-60 is the most suitable for separation of peptides of…

  • C8 is the most commonly used column type following C18. YMC Octyl columns are prepared from exhaustive bonding of a monomeric octylsilane to totally spherical and porous silica gels. The functionalized silica is then treated with a endcapping process. This produces a moderate 10% carbon loading on…

  • YMC-Triart C18 is a hybrid silica-based ODS column emphasizing durability, low operating pressure, and excellent performance. YMC-Triart C18 has been developed and is manufactured using state-of-the-art technologies that define materials, granulation, and surface modification. Application: For…

  • YMC-Pack CN can be used in both normal-phase and reversed-phase modes, since it has cyanopropyl group of medium polarity chemically bonded to the stationary phase. It can be used in normal phase mode with low-polarity mobile phase such as hexane. It can also be used in reversed-phase mode with…

Compare Tool

Select up to 3 products